DOK-MOTOR*-MSK*EXGIIK3-PR09-EN-P
Synchronous Servomotors MSK For Potentially Explosive Areas
12
Delivery condition, identification, handling
12.1
Delivery condition
12.1.1
General information
12.1.2
Factory inspection
Electrical testing
Mechanical testing
12.1.3
Customer inspection
Upon delivery, MSK motors are packed in cartons or wooden boxes. Packing
units on pallets are secured with straps.
CAUTION
Maintain a sufficient distance and carefully cut the bandages.
Motor shaft and plug connections are provided with protective sleeves ex
works. Only remove the protective sleeves immediately before starting as‐
sembly.
Factory testing of MSK motors includes:
●
High-voltage test
●
Insulation resistance test
●
Protective conductor connection
●
Winding resistance test
●
Concentricity and position tolerances of shaft end and mounting flange
●
Axial run-out of the flange surface to the shaft
●
Coaxiality of the centering edge to the shaft
●
Brake holding torque test (option)
Since all MSK motors are subjected to a standardized test procedure, high-
voltage tests by the customer are not necessary. Repeated high-voltage tests
can damage motors and components.
NOTICE
Avoid repeated inspections.
Please observe the target values of the EN 60034-1.
Bosch Rexroth AG
Delivery condition, identification, handling
Injuries due to uncontrolled movement of the
retaining straps when cutting!
Destruction of motor components due to im‐
properly executed high-voltage inspection! In‐
validation of warranty!
145/175