Display shows CO/CO CALL TIME and three digits of timer length.*
3.
Enter three digits of time duration.
4.
Press # key.
(* Default: 000 minutes. If set at 000, the system requires a DISCONNECT CLEAR signal from the
line provider to clear the lines after a call is terminated. It is recommended that an 800 msec clear
signal is provided.)
Note: Recalls to operator will be automatically disconnected if not answered before this timer expires.
# 59 External Call Forward Timer
When program # 45 has one or more lines set for external call forward, use program # 59 to delay the
forwarding feature. This will allow the customer time to answer the line before it is externally
forwarded.
1.
Press # key.
PROGRAMMING is displayed.
2.
Dial 59.
EXT DLY TIME is displayed momentarily, then the current timer value 'xxx SEC'.*
3.
Enter three digits of new delay time in range 0 to 200 seconds. (A value of 200 s indicates
that the timer setting is indefinite, i.e. timer does not expire.)
4.
Press # key.
(*Default: 30 s)
# 60 C.O. Line Ring Mode
Assigns an incoming ring mode for each C.O. line.
1.
Press # key.
PROGRAMMING is displayed.
2.
Dial 60.
Display shows TRUNK RING MODE.
3.
Press desired C.O. line button and current ring mode is displayed.
4.
Enter new data for that line.*
0 = Individual ring mode
1 = Conditional ring mode
2 = Unconditional ring mode
3 = Distributed ring mode.
5.
Press # key.
6.
Repeat for each line in the system.
*Individual ring mode: