Samsung NX-308 Programming & Installation Manual page 33

Hide thumbs Also See for NX-308:
Table of Contents

Advertisement

2.
Dial 26.
NIGHT TOLL is displayed and then the current data indicating class of dialling.
3.
Enter technician-level password.
4.
Enter digit.
0 = Same as day mode operation
1 = All stations class B
2 = All stations class C
3 = All stations class D
4 = All stations class E
Press  key.
5.
(Default: 0)
# 30 Class Of Service
Assigns an individual dialling class of service to each station.
Press  key.
1.
PROGRAMMING is displayed.
2.
Dial 30.
Display shows STATION TOLL CALL followed by eight digits, each of which indicates the
class of service of each station.*
0 = Class A:
1 = Class B:
2 = Class C:
3 = Class D:
4 = Class E:
3.
Enter all eight digits to set class of service for each station.
Press  key.
4.
(*Default: All Class A  00000000)
# 31 C.O. Line Access
Designates which stations have access to C.O. lines on a station by station basis.
Press  key
1.
PROGRAMMING is displayed.
2.
Dial 31.
TRUNK ACCESS is displayed.
3.
Press DSS key of station to be programmed.
No Restriction
Follows allow/deny table for class B
(programs  33, # 34)
Deny table has a priority over allow table
Follows another allow/deny table for class C
(programs  35, # 36)
Follows allow table for class D
(program  37)
Intercom call only
31

Advertisement

Table of Contents
loading