Installing The Noise Reduction Module In The Lower Part Of An A63B Cabinet - Huawei OptiX OSN 9800 U32 Enhanced Subrack V100 Quick Installation Manual

Hide thumbs Also See for OptiX OSN 9800 U32 Enhanced Subrack V100:
Table of Contents

Advertisement

Installing the Cabinet
7.3

Installing the Noise Reduction Module in the Lower Part of an A63B Cabinet

NOTE
After installing the bolts on the cabinet, perform the following steps to install the noise reduction module.
Push the lower part
According to the indication on module
innermost position of the cabinet and put it down.
(Clockwise) Fasten the four screws to secure the noise reduction module.
M6
2# screwdriver
2.04±0.20 N· m
of the noise reduction module to the innermost position of the cabinet and put it down.
, push the lower part
of the noise reduction module to the
25