The method for connecting/disconnecting the MPO connector is as follows:
- For connecting the connector, push the shell to upper side.
- For disconnecting the connector, pull the coupling nut to lower side.
Shell
Connecting UDA Cable
To connect a UDA cable, do the following:
Prerequisites
Before proceeding with connecting the UDA cable, make sure that you have the
items mentioned in the table below:
Table 29.
Parts and Tools for Connecting UDA Cable
Category
Installation Section
Cable
Minimum Cable
bend Radius
Connector
Working Tools
The table below outlines the UDA cable pin map:
Table 30.
UDA Cable Pin Map
System Side
1
2
3
5G NR HRU Installation Manual v1.0
Copyright © 2018, All Rights Reserved.
Push
Description
HRU UDA Port to External alarm device
UDA Cable Assembly (24 AWG, 5C)
5 × OD
External alarm device
HRU
 Cable Cutter
 Wire Stripper
 Nipper
 LAN Tool
Color Map
White/Blue
Blue
Orange
Coupling Nut
Pull
Check specifications of external device output terminal
per site and prepare fasteners.
JONHON, Push Pull Type, RJ45MF-CT-07
Description
UDA Common RTN
UDA3
UDA2
Confidential