PART 6. CONNECTING STATION EQUIPMENT
6.1 SAFETY PRECAUTIONS
To limit the risk of personal injury, always follow these precautions before connecting
telephone circuits:
a. Never install telephone wiring during a lightning storm.
b. Never install telephone jacks in a wet location unless the jack is specifically
designed for wet locations.
c. Never touch non-insulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.
d. Use caution when installing or modifying telephone lines.
6.2 KEYSETS
Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each keyset
to the DLI port
(see Figures 6–1a and 6–1b)
(see section 8 of this installation section).
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger telecommu-
nication line cord.
NOTE: Because the iDCS 500 is a self-configuring system, if you connect a 12 button
keyset to a DLI port that previously had a 24 button keyset installed, the existing data
will be rewritten with 12 button keyset default data (MMC 723). This can be avoided if
you first SAVE the keyset data using MMC 720. This rule also applies to the iDCS family
of keysets.
6.3 DCS 32 BUTTON ADD-ON MODULES
Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each add-on
module (AOM) to the DLI port
your choice
(see part 8 of this installation section).
alone unit, there is nothing else required other than assigning soft keys. When an AOM
is to be used with a station, it must be assigned to that station in MMC 209. Add-on
modules can be assigned to any keyset or single line telephone.
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger telecommu-
nication line cord.
or plug into the KDb-DLI of your choice
(see Figure 6–2a or 6–2b)
If an AOM is to operate as a stand-
6.1
Home Page
INSTALLATION
PART 6 MARCH 2004
or plug into the KDb-DLI of