PART 1. SITE REQUIREMENTS
When you are planning the installation of the iDCS 500 Release 2 system, choose a site
that meets the following requirements:
• Select a location for the iDCS 500 system that has enough space for easy
installation and adequate lighting
Select a location that will minimize cable lengths.
Table in the iDCS 500 Release 2 General Description Section.
• The equipment should not be exposed to direct sunlight, corrosive fumes, dust,
constant vibration or strong magnetic fields such as those generated by motors and
copy machines.
• A direct commercial AC power outlet is required. Do not use extension cords.
Preferably, a dedicated circuit should be used to minimize the risk of other electrical
equipment being connected that could adversely affect system operation.
• Ensure that all wires and cables going to and coming from the iDCS 500 are
properly routed. Do not cross fluorescent lights or run parallel with AC wires.
• The equipment must be located in an environment that will maintain a temperature
range of 32°–104°F (0°–40°C) and a humidity range of 10%–90% non-condensing.
• This equipment is to be installed only in Restricted Access Areas (Dedicated
Equipment Rooms, Equipment Closets, or the like) in accordance with articles 110-
16, 110-17 and 110-18 of the National Electric Code, ANSI/NFPA 70.
• Allow at least 10" clearance on both sides and 10" clearance on top of the system to
ensure proper ventilation and access to the interior of the cabinet.
• Do not install in close proximity to a fire sprinkler head or to other sources of water.
• Space consideration must be made to allow floor or wall mounting. Do not wall
mount a multiple cabinet system.
Meeting these requirements will help to ensure proper performance and greater life
expectancy of the system.
(see Figure
1–1).
See the Cable Requirements
1.1