DTC B1141 / DTC B1142 (No. 1141 / No. 1142) Outside Air Temperature (Ambient Temp.) Sensor
Circuit Malfunction
Wiring Diagram
1
G30
12
11
10
9
8
7
6
24
23
22
21
20
19
18
17
G32
6
5
4
3
2
15
14
13
12
11
10
9
DTC Detecting Condition and Possible Cause
DTC detecting condition
DTC B1141 (DTC No. 1141):
Input signal from outside air temperature sensor is higher
than 4.88 V.
DTC B1142 (DTC No. 1142):
Input signal from outside air temperature sensor is lower
than 0.1 V.
Flow Test Description
Step 1: Check whether malfunction is in outside air temperature sensor.
Step 2: Check outside air temperature sensor circuit.
2
5V
WHT/BLK
G31-24
BLK/RED
G31-21
5
4
3
2
1
16
15
14
13
1
8
7
2
1. Outside air temperature sensor
2. BCM
Body Electrical Control System:
3
20
19
18
17
16
15
14
13
12
40
39
38
37
36
35
34
33
32
3. Outside air temperature sensor connector
Possible cause
• Open in outside air temperature sensor circuit
• Outside air temperature sensor malfunction
• BCM malfunction
• Short in outside air temperature sensor circuit
• Outside air temperature sensor malfunction
• BCM malfunction
S5JB0EA204009
1
G31
11
10
9
8
7
6
5
4
3
2
1
31
30
29
28
27
26
25
24
23
22
21
I5JB0AA20007-01