EPSON Stylus COLOR 900/900N
After the test pattern prints (see
page 131), the head angular adjustment menu returns:
Table 5-7. Head Angular Adjustment Menu
1. Select Head angular adjustment. The software prompts you to
loosen the left head fixing screw:
Figure 5-16. Reminder to Loosen the Left Head Fixing Screw
"Checking the Printhead Angle"
on
2. Loosen the screw by rotating it one-quarter to one-half turn. Do not
remove it completely. See the figure below.
Figure 5-17. Loosening the Left Head Fixing Screw
3. After loosening the screw, press Enter. The carriage moves to the
left and the software prompts you to loosen the right head fixing
screw:
Figure 5-18. Reminder to Loosen the Right Head Fixing Screw