COPIER (Service mode for printer) > ADJUST (Adjustment mode) > DENS
CONT-Y
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
CONT-M
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
CONT-C
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
CONT-K
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
ATR Sensor (Y) control voltage entry
To enter the density detection control voltage of the ATR Sensor (Y).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after the processing is done
Enter the setting value, and then press OK key.
The value changes if the Developing Unit is initialized (INISET-Y/4).
0 to 255
V
123 (It may vary by initialization of the Developing Unit when clearing RAM data.)
COPIER> FUNCTION> INSTALL> INISET-Y/4
ATR Sensor (M) control voltage entry
To enter the density detection control voltage of the ATR Sensor (M).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after the processing is done
Enter the setting value, and then press OK key.
The value changes if the Developing Unit is initialized (INISET-M/4).
0 to 255
V
122 (It may vary by initialization of the Developing Unit when clearing RAM data.)
COPIER> FUNCTION> INSTALL> INISET-M/4
ATR Sensor (C) control voltage entry
To enter the density detection control voltage of the ATR Sensor (C).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after the processing is done
Enter the setting value, and then press OK key.
The value changes if the Developing Unit is initialized (INISET-C/4).
0 to 255
V
121 (It may vary by initialization of the Developing Unit when clearing RAM data.)
COPIER> FUNCTION> INSTALL> INISET-C/4
ATR Sensor (Bk) control voltage entry
To enter the density detection control voltage of the ATR Sensor (Bk).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after the processing is done
Enter the setting value, and then press OK key.
The value changes if the Developing Unit is initialized (INISET-K/4).
0 to 255
V
120 (It may vary by initialization of the Developing Unit when clearing RAM data.)
COPIER> FUNCTION> INSTALL> INISET-K/4
629
8. Service Mode