E014-0002-05
Detection Description
Remedy
E014-0003-05
Detection Description
Remedy
Fixing Motor error
The specified speed could not be maintained although it became the specified speed at least once
from the startup of the Fixing Motor.
[Related parts]
- Harness between the DC Controller PCB (UN049/J123) and the Fixing Motor (M09)
- Fixing Unit
- Gears in the Fixing Unit
- Cam/21T Gear
- 36T Gear
- Fixing Drive Unit
- Fixing Motor (M09)[7200-0014]
- DC Controller PCB (UN049)
- Power Supply Unit (UN01)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check that the Fixing Unit is pushed into the host machine so the handle is locked.
2. Remove the Fixing Unit, and rotate the Cam/21T Gear and the 36T Gear by hand to visually
check that there is no missing teeth or abnormal abrasion.
3. Replace the Fixing Unit.
4. Check the harness between the DC Controller PCB and the Fixing Motor.
5. Measure the both ends of the fuse in the Low Voltage Power Supply Unit using a tester.
a. If the measurement value is less than 1 ohm (conduction state),
a-1. Replace the Fixing Motor.
a-2. Replace the DC Controller PCB.
b. If the measurement value is 1 ohm or higher (non conduction state), replace the Power Supply
Unit.
Fixing Motor error
There was no FG signal input from the startup of the Fixing Motor.
[Related parts]
- Harness between the DC Controller PCB (UN049/J123) and the Fixing Motor (M09)
- Fixing Unit
- Gears in the Fixing Unit
- Cam/21T Gear
- 36T Gear
- Fixing Drive Unit
- Fixing Motor (M09)[7200-0014]
- DC Controller PCB (UN049)
- Power Supply Unit (UN01)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check that the Fixing Unit is pushed into the host machine so the handle is locked.
2. Remove the Fixing Unit, and rotate the Cam/21T Gear and the 36T Gear by hand to visually
check that there is no missing teeth or abnormal abrasion.
3. Replace the Fixing Unit.
4. Check the harness between the DC Controller PCB and the Fixing Motor.
5. Measure the both ends of the fuse in the Low Voltage Power Supply Unit using a tester.
a. If the measurement value is less than 1 ohm (conduction state),
a-1. Replace the Fixing Motor.
a-2. Replace the DC Controller PCB.
b. If the measurement value is 1 ohm or higher (non conduction state), replace the Power Supply
Unit.
338
7. Error/Jam/Alarm
Need help?
Do you have a question about the imageRUNNER ADVANCE C3500 III Series and is the answer not in the manual?
Questions and answers
J ai un code e602-5001 sur une canon c5240i
The error code E602-5001 for the Canon imageRUNNER ADVANCE C3500 III Series indicates an Encryption Chip error.
This answer is automatically generated