Temp; Time [Hh:mm:ss] - GE MDS 4790 Series Installation & Operation Manual

400 mhz/900 mhz multiple address system master station radio
Table of Contents

Advertisement

Unit's Internal
Temperature
Clock Formatting
MDS 05-3438A01, Rev. F
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx
The table below gives the text message displayed by the
command for each alarm event.
STAT
Table 13. Text Messages of Alarm Event Codes
Event
Number
01
02
03
04
06
07
08
10
12
13
15
16
17
18
20
25
26
27
28
31

TEMP

A
B
This command displays the radio's internal temperature in degrees Cel-
sius. Note that the radio is designed to operate in a range from –30 C° to
+60 C°, and may fail at temperatures outside this range. This internal
reading might be higher than the outside temperature by several degrees.

TIME [hh:mm:ss]

This command sets or displays the time in 24-hour format. The accuracy
of the date and time are important because events are logged with the
date and time (see
"DATE [mmm dd yyyy]" on Page
MDS 4790/9790 Series I/O Guide
Text Message
Hardware mismatch
Model number not programmed
Authorization fault
Synthesizer out-of-lock
A/D fault
Voltage regulator fault detected
Radio not calibrated
EEPROM write failure
Receiver timeout
Transmitter timeout
Output power fault
Unit address not programmed
Data parity error
Data framing error
Configuration error
10V regulator output not in valid
range
DC input power is not in valid range
LNA current is not in valid range
Board current not in valid range
Internal temperature not in valid
range
Show Temperature and
Voltages
Set Time
A
B
screen,
Page 78
screen,
Page 77
44).
57