HUAWEI MU509 Series HSDPA LGA Module
Hardware Guide
Figure 3-3 VCOIN interface circuit

3.3.5 Output Power Supply Interface

Output power supply interface includes VCC_EXT1, VCC_EXT2 and SIM_VCC.
Through the output power supply interface, the MU509 module can supply 2.6 V and
1.8 V power externally with an output current of 20 mA (typical value) for external level
conversion or other applications.
If the MU509 module is in sleep mode, the output power supply interface is in the low
power consumption state (< 500 μA). If the MU509 module is in power down mode,
the output power supply is in the disabled state.

3.4 Signal Control Interface

3.4.1 Overview

The signal control part of the interface in the MU509 module consists of the following:
Table 3-5 lists the pins on the signal control interface.
Issue 09 (2014-03-06)
VCOIN
Module
(DCE)
Power-on/off (POWER_ON_OFF) pin
Hardware reset (RESIN_N) pin
Network status LED (LED_STATUS/LED_MODE) pin
WAKEUP_IN Signal (WAKEUP_IN) pin
WAKEUP_OUT Signal (WAKEUP_OUT) pin
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description of the Application Interfaces
R
2.2 kΩ
100 nF
+
Coin Cell
-