Exhaust Gas Temperature Before Turbine; Turbocharger Speed - ABB TPS48-H33 Operation Manual

Hide thumbs Also See for TPS48-H33:
Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
4
Monitoring operation
4.2

Exhaust gas temperature before turbine

Factors influencing replacement intervals
Operation above the operating limits defined on the rating plate can shorten
the recommended replacement intervals considerably.
CAUTION
Measure exhaust gas temperature upstream of turbine.
Comply with operating limits on rating plate.
Definition and explanations concerning rating plate: refer to chapter 2 of Operation Manual /
Safety.
Operating limits: refer to chapter 3 of Operation Manual / Safety data sheet or examine
rating plate.
4.3

Turbocharger speed

4.3.1
Introduction
A speed measuring system enables the constant monitoring of the turbocharger speed.
Do not strain cables
If you pull the speed measurement cables too hard, contacts can be pulled
out.
CAUTION
Do not strain the speed measurement cables by pulling.
Machine damage
Operation above the operating limits defined on the rating plate can shorten
the recommended replacement intervals considerably and cause machine
CAUTION
damage.
Measure turbocharger speed.
Comply with operating limits on rating plate.
Definition and explanations concerning rating plate: refer to chapter 2 of Operation Manual /
Safety.
Operating limits: refer to chapter 3 of Operation Manual / Safety data sheet or examine
rating plate.
If no speed measurement system is present, the system below can be ordered from an ABB
Turbocharging Service Station (see chapter Ordering spare parts [➙ 93]).
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Page 25 / 99
Revision A
August 2016