Removing The Turbocharger - ABB TPS48-H33 Operation Manual

Hide thumbs Also See for TPS48-H33:
Table of Contents

Advertisement

Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
2
Removing and Installing
2.2

Removing the turbocharger

Danger of burns
Touching hot surfaces or contact with hot operating fluids can cause burns.
Do not touch hot surfaces. Observe the warning plate on the turbo-
WARNING
charger.
Wear heat-resistant safety gloves and protective clothing.
Wait for the turbocharger to cool down before carrying out any work.
Wear safety gloves to protect against thermal hazards.
Do not strain cables
If you pull the speed measurement cables too hard, contacts can be pulled
out.
CAUTION
Do not strain the speed measurement cables by pulling.
Gas outlet casing (61001)
The gas outlet casing (61001) can remain fitted in the exhaust gas pipe if the
locking to the turbine casing is accessible. Otherwise the complete turbo-
NOTICE
charger unit including gas outlet casing must be removed.
Disconnect all pipes according to the instructions of the enginebuilder.
Version with water-cooled bearing casing:
Loosen and remove water connections.
Close the openings of the water connections with screw plugs.
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Page 12 / 99
Revision A
August 2016