Points to use the wave output function

When CH1 Output enable/disable flag (Y1) is turned on or off during the wave output
When 'CH1 Output enable/disable flag' (Y1) is turned on and off during the wave output, the analog output value becomes the
offset value and the wave output does not stop. The wave output continues to be updated while 'CH1 Output enable/disable
flag' (Y1) is off. When 'CH1 Output enable/disable flag' (Y1) is turned off and on, the analog output restarts.
CH1 D/A conversion enable/disable
setting (Un\G500)
CH1 Output enable/disable
flag (Y1)
CH1Wave output start/stop request
(Un\G462)
CH1 Wave output status monitor
(Un\G401)
Wave data
1 FUNCTIONS
64
1.14 Wave Output Function
CPU module status
OFF
Wave output stop
request (0)
Wave output stop (0)
Analog output
Output set in CH1 Output setting
during wave output stop
(Un\G524)
Offset value
RUN
D/A conversion enable (0)
OFF
ON
ON
Wave output start request (1)
Wave output
Wave output (1)
stop (0)