Relevant Manuals; Terms - Mitsubishi Electric MELSEC iQ-R Series User Manual

Melsec iq-r digital-analog converter modul
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

RELEVANT MANUALS

Manual name [manual number]
MELSEC iQ-R Digital-Analog Converter Module User's
Manual (Application)
[SH-081237ENG] (this manual)
MELSEC iQ-R Digital-Analog Converter Module User's
Manual (Startup)
[SH-081235ENG]
MELSEC iQ-R Programming Manual (Module Dedicated
Instructions)
[SH-081976ENG]
e-Manuals are electronic book-type manuals for Mitsubishi Electric FA products that can be read with a
dedicated tool.
The following shows the features of e-Manuals.
• Desired information can be searched for from multiple manuals at a time. (Manual cross search)
• Other manuals can be referred to from links in a manual.
• Desired hardware specifications can be checked from each part in the illustrations of products.
• Information frequently referred to can be registered as a favorite.
• Sample programs can be copied to an engineering tool.

TERMS

Unless otherwise specified, this manual uses the following terms.
Term
D/A converter module
GX Works3
Watchdog timer error
Engineering tool
Factory default setting
Normal mode
Offset/gain setting mode
Synchronization normal output mode
Buffer memory
User range
R mode
Q compatible mode
Global label
Module label
Remote head module
14
Description
Functions, parameter setting, troubleshooting, I/O signals, and buffer
memory of the D/A converter module
Specifications, procedures before operation, wiring, operation example,
and offset/gain setting of the D/A converter module
Dedicated instructions for the intelligent function modules
Description
The abbreviation for the MELSEC iQ-R series digital-analog converter module
The product name of the software package for the MELSEC programmable controllers
An error that occurs if the internal processing of the D/A converter module is abnormal. Watchdog timer enables
the module to monitor its own internal processing.
A generic term for GX Works3
A generic term for analog output ranges of 0 to 10V, 0 to 5V, 1 to 5V, -10 to 10V, 0 to 20mA, and 4 to 20mA
Setting values of the operation mode setting: normal mode and offset/gain setting mode
When the inter-module synchronization function target is enabled, a value is set to CH Synchronization digital
value using a synchronous interrupt program and the value is output on the set synchronization cycle.
A memory in an intelligent function module, where data (such as setting values and monitoring values)
exchanged with a CPU module are stored
An analog output range where any value can be set. Set the user range in the offset/gain setting.
A mode that the module operates with the buffer memory map that memory areas have been newly laid out in the
MELSEC iQ-R series.
A mode that the module operates with the buffer memory map converted to the equivalent map of the MELSEC-
Q series.
A label that is valid for all program data created in the project. The global label has two types: a module specific
label (module label) generated automatically by GX Works3, and an optional label for which any device can be
specified.
A label that represents a memory (I/O signals and buffer memory areas) specific to each module in a given
character string. Through the module used, GX Works3 automatically generates this label, which can be used as
a global label.
The abbreviation for the RJ72GF15-T2 CC-Link IE Field Network remote head module
Available form
Print book
e-Manual
PDF
Print book
e-Manual
PDF
e-Manual
PDF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60dav8R60da4R60dai8

Table of Contents