(5) See below for the [Maintenance Forecast 2/2] screen. For details of the operation buttons,
see [Table 4-16: Details and Roles of "Maintenance Forecast" Operation Buttons].
【Screen Specifications】
Screen to monitor the dedicated robot input/output (I/O) signals
(1) Back・・・Switches the dedicated signal monitor screens [Dedicated Signal Monitor 2/2]
→[Dedicated Signal Monitor 1/2]
(2) Next・・・Switches the dedicated signal monitor screens [Dedicated Signal Monitor 2/2]
→[Dedicated Signal
(3) Belt・・・Displays the usable time of the belt for driving of J5 axis
(4) Reset・・・Displays 35000 hours for a belt reset
* Belt is useable for up to 35000 hours
(5) Battery・・・Initializes the remaining battery hours inside of the robot controller
(6) Reset・・・Displays 14600 hours to reset the battery
* Battery is useable for up to 14600 hours
(7) Display of Running State・・・Lights the lamp according to the robot running status
* Automatic Operation in Progress (green) Servo Power ON (green) Error (red)
Current operation speed value (%)
(8) UP/DOWN・・・Changes the operation speed in the OVRD DISPLAY UP (speed-up),
DN (speed-down)
(9) Common Buttons・・・Jump to each screen
* "STOP" stop a running program (Servo remains ON)
Monitor 1/2]
(currently unavailable)
(currently unavailable)