Rf Cabinet Earth Ground; Rf Cabinet Alarm, Span Line And Modem Cabling; Input And Output Cabling - Motorola SC 4812ET RF Hardware Installation Manual

Power cabinet
Table of Contents

Advertisement

Cabinet Cabling
– continued
Figure 5-4: Antenna Panel Detail (Rear View)
5
RF Cabinet Alarm, Span Line
and Modem Cabling
Input and Output
Cabling
90
The objective of this procedure is to install the RF Cabinet alarm ,span
line and modem cabling.
Figure 5-5 details the location of the punch block, the input and output
pin identification, wire pair identification, and how the wires are inserted
for termination.
SC
4812ET RF and Power Cabinet Hardware Installation Manual
TM
WARNING
Use only 110 style punch block punch tool to terminate
wires at punch block (ref: P/N CGDS237744 or
equivalent).
CAUTION
To ensure protection from surges, ground connection is
required before connecting any incoming telecom lines.
DRAFT
Route Ground
Cable Through
This Slot.