Enclosure Dimensions; Table 1-5: Cabinet Dimension - Motorola SC 4812ET RF Hardware Installation Manual

Power cabinet
Table of Contents

Advertisement

Enclosure Dimensions

Height
1677 mm
(66")
1677 mm
(66")
Apr 2001
SC
TM
V02.03
Battery Compartment Fan
The battery compartment fan provides air circulation for the two battery
compartments. It is located on the inside of the battery compartment
door.
Heat Exchanger
The Heat Exchanger provides cooling to the rectifier compartment of the
Power Cabinet. The Heat Exchanger is located in the primary front door
of the Power Cabinet.
Rectifiers
The +27V rectifiers convert the AC power supplied to the Power Cabinet
to +27V DC to power the RF Cabinet and maintain the charge of the
batteries.
AC Load Center (ACLC)
The ACLC is the point of entry for AC Power to the Power Cabinet. It
incorporates AC power distribution and surge protection.
Punch Block
The Punch Block is the interface for the alarm signalling between the
Power Cabinet and the RF Cabinet.
Table 1-5 show the dimensions for the SC 4812ET RF and Power
Cabinet enclosures.
Table 1-5: Cabinet Dimensions
Width
1423 mm
SC4812ET RF Cabinet
(56")
1423 mm
Power Cabinet
(56")
The primary front door of the RF Cabinet and both front
doors of the Power Cabinet are removable. The depth of
the cabinets with the door(s) removed is 711 mm (28").
4812ET RF and Power Cabinet Hardware Installation Manual
DRAFT
Item
Depth
915 mm
(36")
965 mm
(38")
NOTE
Introduction
– continued
Weight (Max)
680 kg
(1500 lbs)
1590 kg
(3500 lbs)
29