L
7.5.9
Write memory
Command
: f <Address>,
<Size>, <Data>
<Address>
: Address to which the data is written (FROM address not possible).
<Size>
: Writing size.
<Data>
: Writing data.
Explanation
: This command is used to write only the amount (<Size>) of <Data> to the memory
designated in <Address>. This command cannot be used to write to the FROM.
Example:
>f Oxa8000000.0x40.0xee fEnter]
z-d Oxa8OOOOOO.Ox5O lEnter1
* Memory details after execution.
a8000000: ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee
*................*
a8000010: eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
*................*
a8000020: ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee ee
*................*
a8000030: eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
*................*
a8000040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
*................*
7.5.10
Clear memory
Command
: c <Address>, <Size>
<Address>
: Memory clear address (FROM address not possible)
<Size>
: Clear size.
Explanation
: This command is used to zero clear only the amount (<Size>) of the memory
designated in <Address>. This command cannot be used to clear the FROM.
Example:
To clear the on-board SFtAM.
>eOxa8000000.0x80000rEntw]
7.5.11
Compare
memory
Command
: v <Address l>, <Address 2>, <Size>
<Address 1~ : Compare address i
<Address 2~ : Compare address 2
cSiie>
: Compare size
Explanation
: This command is used to compare the amount (<Size>) of details in the memory
designated in <Address l> with the memory designated in <Address 2>.
Example:
>v Oxaa400000.0xa800000O.Ox8OOOO IEnter]