Speed control under Real sensorless vector control, vector control, PM sensorless vector control
Torque limit level by communication options (Pr. 810 = "2", Pr. 805, Pr. 806)
● When a communication option (FR-A8NC or FR-A8NCE) is used, the Pr. 805 or Pr. 806 setting is
used as the torque limit value. (Internal torque limit 2)
● When the CC-Link communication (Ver. 2) is used in the quadruple or octuple setting (Pr. 544="14,
18, 114, or 118"), the torque limit value can be input using a remote register (RWwC).
● When the CC-Link IE Field Network is used, the torque limit value can be input using a remote
register (RWw2).
Pr. 804
1
3
5
6
Tab. 5-30:
The torque limit setting is defined as an absolute value.
Can also be set from operation panel or parameter unit.
The torque can also be limited by setting a value in Pr. 805 or Pr. 806.
Setting range if set by operation panel or parameter unit is "673 to 1327 (-327% to 327%)"; setting
increment is 1%.
Fig. 5-17:
5 - 90
Torque limit input
FR-A8NC
PLC function
Torque limit by Pr. 805 or Pr. 806
Torque limit by remote register
(RWwC)
Torque limit by remote register
(RWwC)
Torque limit by Pr. 805 or Pr. 806
Parameter 804 settings
Reverse
regeneration
Pr. 805 (Pr. 806)
RWwC, RWw2
Pr. 805 (Pr. 806)
RWwC, RWw2
Reverse
driving
Reverse
rotation
Torque limit level
FR-A8NCE
Torque limit by remote register
(RWw2)
Torque limit by remote register
(RWw2)
Torque limit
Pr. 805 (Pr. 806)
RWwC, RWw2
quad 1
quad 4
Pr. 805 (Pr. 806)
RWwC, RWw2
quad 3
quad 2
Forward
rotation
Rated speed
Parameters
Setting in-
Setting range
crements
600 to 1400
1 %
(-400 % to 400 %)
-32768 to 32767
(complement of 2)
0,.1 %
(-327.68 % to
327.67 %)
Forward
driving
Speed
Forward
regeneration
I001505E