Parameter List
Pr.
Pr.
Name
group
Terminal 1 added compensation
⎯
242
T021
amount (terminal 2)
Terminal 1 added compensation
⎯
243
T041
amount (terminal 4)
⎯
244
H100
Cooling fan operation selection
245
G203
Rated slip
246
G204
Slip compensation time constant
Constant-power range slip
247
G205
compensation selection
⎯
248
A006
Self power management selection
⎯
249
H101
Earth (ground) fault detection at start
⎯
250
G106
Stop selection
⎯
251
H200
Output phase loss protection selection
252
T050
Override bias
253
T051
Override gain
⎯
254
A007
Main circuit power OFF waiting time
255
E700
Life alarm status display
E701
Inrush current limit circuit life display
256
257
E702
Control circuit capacitor life display
E703
Main circuit capacitor life display
258
E704
Main circuit capacitor life measuring
259
⎯
260
E602
PWM frequency automatic switchover
261
A730
Power failure stop selection
Subtracted frequency at deceleration
262
A731
start
263
A732
Subtraction starting frequency
264
A733
Power-failure deceleration time 1
265
A734
Power-failure deceleration time 2
Power failure deceleration time
266
A735
switchover frequency
⎯
267
T001
Terminal 4 input selection
⎯
268
M022
Monitor decimal digits selection
⎯
269
E023
Parameter for manufacturer setting. Do not set.
Stop-on contact/load torque high-
⎯
270
A200
speed frequency control selection
271
A201
High-speed setting maximum current
272
A202
Middle-speed setting minimum current
273
A203
Current averaging range
274
A204
Current averaging filter time constant
Tab. 5-2:
Parameter overview (by number) (9)
5 - 10
Minimum
Setting range
setting
increments
0 to 100%
0 to 100%
0, 1, 101 to 105
0 to 50%, 9999
0.01%
0.01 to 10 s
0.01 s
0, 9999
0 to 2
0, 1
0 to 100 s, 1000 to 1100 s,
8888, 9999
0, 1
0 to 200%
0 to 200%
0 to 3600 s, 9999
(0 to 15)
(0 to 100%)
(0 to 100%)
(0 to 100%)
0, 1
0, 1
0 to 2, 11, 12, 21, 22
0 to 20 Hz
0.01 Hz
0 to 590 Hz, 9999
0.01 Hz
0 to 3600 s
0 to 3600, 9999
0 to 590 Hz
0.01 Hz
0, 1, 2
0, 1, 9999
0 to 3, 11, 13
0 to 400%
0 to 400%
0 to 590 Hz, 9999
0.01 Hz
1 to 4000
Initial value
Refer
to page
FM
CA
0.1%
100%
5-395
0.1%
75%
5-395
1
1
5-303
9999
5-691
0.5 s
5-691
1
9999
5-691
1
0
5-480
1
0
5-430
0.1 s
9999
5-430
1
1
5-306
0.1%
50%
5-395
0.1%
150%
5-395
1 s
600 s
5-480
1
0
5-222
1%
100%
5-222
1%
100%
5-222
1%
100%
5-222
1
0
5-222
1
1
5-219
1
0
5-580
3 Hz
5-580
60 Hz
50 Hz
5-580
0.1 s
5 s
5-580
0.1 s
9999
5-580
60 Hz
50 Hz
5-580
1
0
5-389
1
9999
5-327
5-489,
1
0
5-494
0.1%
50%
5-494
0.1%
100%
5-494
9999
5-494
1
16
5-494
Parameters