Connecting Stations And Additional; Equipment; Connecting Stations; Cautions For Connecting Stations - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 7

Connecting Stations and Additional

Equipment

This chapter describes how to connect various stations and additional equipment,
such as analog/digital phones, door phones and door locks, to the OfficeServ 7200
system.
1

Connecting Stations

1.1

Cautions for Connecting Stations

Take the following cautions when connecting stations.
Do not connect stations in weather conditions such as storm and lightning.
Do not connect stations in a humid area.
Comply with the manual of the station and with this document when reconnecting
stations or changing connections.
Connect stations to a pair of #24 AWG or #26 AWG cables.
The distances between stations and the OfficeServ 7200 system are as follows:
Digital phone
Analog phone
Door phone
AOM
WBS24
© SAMSUNG Electronics Co., Ltd.

Table 7.1 Distance Between Stations and the System

Station
Distance
Maximum 400 m(for AWG #24)
Maximum 1 km(for AWG #24)
Maximum 400 m(for AWG #24)
Maximum 400 m(for AWG #24)
Maximum 600 m(0.64 twisted cable)
Maximum 400 m(0.40 twisted cable)
Page 7-1