1
Line Conditions
Cautions for connecting C.O. lines are as follows:
Cables with AWG #24 or AWG #26 width should be used as subscriber lines.
When wiring cables in high-humidity areas, remove moisture before wiring.
Cables should be handled carefully to prevent any changes or damages.
Subscriber lines should be kept indoors if possible.
High voltage power lines should not be wired near a subscriber line.
Leak resistance for C.O. lines connected to the OfficeServ 7200 system is as
follows:
Leak Resistance Between Lines
Leak Resistance Between Grounds
© SAMSUNG Electronics Co., Ltd.

Table 6.1 OfficeServ 7200 Line Conditions

Line Condition
Leak Resistance
20 kΩ or higher
20 kΩ or higher
Page 6-1