1.4.3 Stop operation of output axis

If the following causes occur in stopping the output axis during synchronous control,
synchronous control is completed after stops processing for the output axis (BUSY signal is
OFF, axis operation status is standby).
Synchronous alignment must be executed for the output axis to restart the synchronous
control. (Refer to Section 4.5)
The target axis bit of "[Cd.380] Synchronous control start" is turned from ON to OFF.
Software stroke limit error occurrence
Forced stop
Stop group1 to 3
(Note-1): Refer to the "User's Manual (Positioning control)" of each Simple Motion module.
(1) Immediate stop
Md.407 Cam axis current
value per cycle
Md.20 Feed current value
(Cam operation)
Md.22 Feedrate
Cd.380 Synchronous control
start (Target axis bit)
BUSY signal
(Note-1)
(Stop with hardware stroke limit or stop command)
The operation stops without decelerate. The Simple Motion module immediately stops
the command, but the operation will coast for the droop pulses accumulated in the
deviation counter of the servo amplifier.
Chapter1 Outline of Synchronous Control
Stop cause
1 - 14
Stop process
Immediate stop
Deceleration stop