106

Cable Entries

Brake resistor, input and motor cable (per phase) terminal sizes, accepted cable
diameters and tightening torques are given below
Frame
size
Wire size
AWG
R2
up to 6*
R3
up to 6*
R4
up to 4
R5
10...2/0
R6
3/0...350 AWG**
* 6 AWG rigid solid cable, 8 AWG flexible stranded cable
** with cable lugs 6...2/0 AWG, tightening torque 14.8...29.5 lbf ft. Cable lugs are not included in the
delivery. See page 57.
In -0205-3 and -0255-5 units, wire size is 3/0...500 MCM and knockout hole diameter is 3.50 in.

Dimensions, weights and noise

H1 height with gland box, H2 height without gland box.
Frame
size
H1
H2
in.
R2
15.96
14.57
R3
18.54
16.54
R4
23.87
19.29
R5
29.09
23.70
R6
34.65*
27.56
* In -0205-3 and -0255-5 units, H1 is 38.46 in. and weight is 150 lb.
Technical data
U1, V1, W1, U2, V2, W2, R+, R
Knock-out hole Ø
(UL type 1)
in.
1.10
1.14
1.38
1.97
2.40
UL type 1
Width
Depth
in.
in.
in.
6.50
8.89
6.81
10.45
9.45
10.79
10.43
11.26
11.81
15.75
-
Tightening
torque
lbf ft
0.9...1.1
0.9...1.1
1.5...3.0
11.1
14.8...29.5
Weight
Height
lb
in.
20
20.78
31
20.78
57
30.49
75
30.49
148*
36.34
.
Earthing PE
Wire size
AWG
up to 8
up to 8
up to 5
10...2/0
4/0
UL type 12
Width
Depth
Weight
in.
in.
10.35
9.49
34
10.35
10.74
41
14.84
10.94
73
14.84
12.14
112
16.52
16.54
170
Tightening
torque
lbf ft
1.1
1.1
2.2
11.1
5.9
Noise
lb
dB
62
62
62
65
65