B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 12 of 69)
ADDR
REGISTER NAME
Security (Read/Write)
32A0
Supervisor Alphanumeric Password Entry
Security (Read/Write Setting)
32AA
Engineer Alphanumeric Password Setting
Security (Read Only)
B
32B4
Engineer Alphanumeric Password Status
Security (Read/Write)
32B5
Engineer Alphanumeric Password Entry
Security (Read/Write Setting)
32BF
Operator Alphanumeric Password Setting
Security (Read Only)
32C9
Operator Alphanumeric Password Status
Security (Read/Write)
32CA
Operator Alphanumeric Password Entry
Security (Read/Write Setting)
32D4
Observer Alphanumeric Password Setting
Security (Read Only)
32DE
Observer Alphanumeric Password Status
Security (Read/Write)
32DF
Observer Alphanumeric Password Entry
Security (Read Only)
32E9
Reserved for password settings of future roles (63 items)
3328
Security Status Indicator
Security (Read/Write Setting)
3329
Session Lockout
332A
Session Lockout Period
332B
Load Factory Defaults
332C
Syslog Server IP Address
332E
Syslog Server Port Number
Security Supervisory (Read/Write Setting)
3331
Device Authentication Enable
3332
Supervisor Role Enable
3333
Lock Relay
3334
Factory Service Mode Enable
3335
Failed Authentication Alarm Enable
3336
Firmware Lock Alarm
3337
Settings Lock Alarm
3338
Bypass Access
3339
Encryption
333A
Serial Inactivity Timeout
Security Command (Read/Write Command)
3350
Operator Logoff
3351
Engineer Logoff
3352
Administrator Logoff
3353
Clear Security Data
Security Reserved Modbus Registers (Read/Write)
3360
Address 0x3360 reserved for serial login (20 items)
3374
Address 0x3374 reserved for serial logout
Security Reserved Modbus Registers (Read Only)
3375
Address 0x3374 reserved for serial logout
Event Recorder (Read Only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
B-20
RANGE
---
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
0 to 65535
0 to 65535
0 to 99
0 to 9999
0 to 1
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 9999
0 to 1
0 to 1
0 to 1
0 to 1
0 to 9999
0 to 9999
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
1
F202
---
1
F001
---
1
F618
---
1
F001
min
1
F001
---
1
F126
---
1
F003
---
1
F001
---
1
F126
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F628
---
1
F102
min
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F001
---
1
F001
---
1
F617
---
1
F003
---
1
F003
---
1
F050
DEFAULT
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
0
0
3
3
0 (No)
0
514
1 (Yes)
0 (Disabled)
0 (Disabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (Disabled)
1 (Enabled)
1
0 (No)
0 (No)
0 (No)
0 (No)
3
3
3 (Engineer)
0
0
0
GE Multilin