GE T60 Instruction Manual page 576

Transformer protection system ur series
Hide thumbs Also See for T60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 8 of 69)
ADDR
REGISTER NAME
21E2
Breaker 1 Arcing Current Phase B
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E4
Breaker 1 Arcing Current Phase C
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E6
Breaker 1 Operating Time Phase A
B
21E7
Breaker 1 Operating Time Phase B
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21EE
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21F0
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21F2
...Repeated for module number 2
Breaker Arcing Current Actual Values (Read Only Non-Volatile) (4 modules)
21FA
...Repeated for module number 3
21FE
...Repeated for module number 4
Breaker Arcing Current Commands (Read/Write Command) (4 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
2226
Breaker 3 Arcing Current Clear Command
2227
Breaker 4 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Transformer Differential and Restraint (Read Only)
2300
Transformer Reference Winding
2301
Transformer Differential Phasor Iad Magnitude
2302
Transformer Differential Phasor Iad Angle
2303
Transformer Restraint Phasor Iar Magnitude
2304
Transformer Restraint Phasor Iar Angle
2305
Transformer Differential 2nd Harm Iad Magnitude
2306
Transformer Differential 2nd Harm Iad Angle
2307
Transformer Differential 5th Harm Iad Magnitude
2308
Transformer Differential 5th Harm Iad Angle
2309
Transformer Differential Phasor Ibd Magnitude
230A
Transformer Differential Phasor Ibd Angle
230B
Transformer Restraint Phasor Ibr Magnitude
230C
Transformer Restraint Phasor Ibr Angle
230D
Transformer Differential 2nd Harm Ibd Magnitude
230E
Transformer Differential 2nd Harm Ibd Angle
230F
Transformer Differential 5th Harm Ibd Magnitude
2310
Transformer Differential 5th Harm Ibd Angle
2311
Transformer Differential Phasor Icd Magnitude
2312
Transformer Differential Phasor Icd Angle
2313
Transformer Restraint Phasor Icr Magnitude
2314
Transformer Restraint Phasor Icr Angle
2315
Transformer Differential 2nd Harm Icd Magnitude
2316
Transformer Differential 2nd Harm Icd Angle
2317
Transformer Differential 5th Harm Icd Magnitude
2318
Transformer Differential 5th Harm Icd Angle
Transformer Thermal Inputs Actual Values (Read Only)
2330
Transformer Top Oil Temperature
B-16
RANGE
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 6
0 to 30
-359.9 to 0
0 to 30
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 30
-359.9 to 0
0 to 30
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 30
-359.9 to 0
0 to 30
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 999.9
-359.9 to 0
0 to 300
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F001
pu
0.001
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
pu
0.001
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
% fo
0.1
F001
degrees
0.1
F002
°C
1
F002
DEFAULT
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0 (No)
0 (No)
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0