3.3.3

L devices

The L devices are bit devices into which user data are stored.
All of these devices can be used as a user area.
List of L devices and differences in address specification by data format
The following shows the L devices (virtual devices inside the GOT).
The address specification values different depending on the data format are also given below.
Address
b7
b6
b5
b4
L7
L6
L5
L4
L15
L14
L13
L12
L23
L22
L21
L20
L31
L30
L29
L28
:
L2039
L2038
L2037
L2036
L2047
L2046
L2045
L2044
*1
For the address specification method for each data format, refer to the following.
• Formats 1, 2
• Formats 3, 4
• Formats 5
• Formats 6, 7
• Formats 8, 9
*2
For reading or writing data in word units, specify the addresses in 16-point units. (Example: L0, L16, L32, etc.)
b3
b2
b1
b0
L3
L2
L1
L0
L11
L10
L9
L8
L19
L18
L17
L16
L27
L26
L25
L24
L2035
L2034
L2033
L2032
L2043
L2042
L2041
L2040
3.4 Message Formats
: GOT-A900 Series microcomputer connection
: GOT-F900 series microcomputer connection
: Digital Electronics Corporation's memory link method
: 4E frame
: QnA compatible 3E frame
3. MICROCOMPUTER CONNECTION (ETHERNET)
Address specification value
Format3, 4
Format
When GS580.b8,
1, 2
GS581.b8, GS582.b8, or
GS583.b8 is ON
A000
H
8192
A001
H
A002
H
8193
A003
H
:
:
A0FE
H
8319
A0FF
H
3.3 Device Data Area
*1
Format
When GS580.b8,
5
GS581.b8, GS582.b8, or
GS583.b8 is OFF
A001
H
2000
H
A000
H
A003
H
2001
H
A002
H
:
:
A0FF
H
207F
H
A0FE
H
3
Format
6 to 9
Same as
address
column
*2
on left
3 - 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents