Chapter 3
Operation

Selecting Manual Exposure Settings

Figure 3-5
Manual Exposure Page
Step 1
Place your mouse pointer over the Imaging tab.
Step 2
Select Exposure from the drop-down menu.
Step 3
Select the Manual mode.
Move the Analog Gain slider to the desired position. Increasing the gain increases the brightness of the
Step 4
image, but it also increases the amount of noise in the image. The analog gain range is 1.00 to 15.75; the
default setting is 1.00.
Step 5
Move the Exposure Time slider to the desired position. This setting is the maximum time in milliseconds
that the sensor is exposed to the light. Decreasing the maximum exposure time decreases the light
sensitivity. The exposure time range is 0.01 to 1000 msec; the default setting is 33 msec.
Set the Day Night Position setting.
Step 6
Refer to the following section for more information:
OL-22669-01
Day: Sets the IR filter to the Day (color) position.
Night: Sets the IR filter to the Night (black-white) position.
Day Night Settings, page 3-18