BENDIX/KING
C.
Recommended Cleaning Procedures
FREON TF, IMC
CARBON TETRACHLORIDE
CHLOROFORM
TRICHLOROETHYLENE
PROPYL ALCOHOL
ETHYL ALCOHOL
XYLENE
Page 5-24
CAUTION:
DO NOT ALLOW SOLVENT TO RUN INTO
SLEEVES OR CONDUIT THAT COVERS
WIRES CONNECTED TO INSERT TERMI-
NALS.
1.
Exterior
(a)
Wipe dust cover and front panel with a lint-free cloth damp-
ened with denatured alcohol.
(b)
For cleaning connectors, use the following procedure.
(1)
(2)
(3)
(4)
(c)
Remove cover(s).
(d)
If necessary, open any blocked ventilation holes by first sat-
urating the debris clogging the aperatures with denatured al-
cohol and then blowing the loosened material out with an air
stream.
2.
Interior
The following solvents are no longer recommended for
benchtop or rework cleaning of printed circuit boards, mod-
ules, or sub-assemblies.
TABLE 5-2 UNSAFE CLEANING AGENTS
15599M00.JA
Wipe dust and dirt from bodies, shells, and cable
clamps using a lint-free cloth moistened with dena-
tured alcohol.
Wipe parts dry with a clean, dry lint-free cloth.
Remove dirt and lubricant from connector inserts, in-
sulation, and terminals using a small soft bristled
brush moistened with denatured alcohol.
Dry the inserts with an air jet.
TRICHLOROETHANE
DETERGENT (ALL AND EQUIVALENTS)
METHYLENE CHLORIDE
GENESOLV 2004/2010
METHYL ALCOHOL
BUTYL ALCOHOL
PRELETE (CFC-113)