Adc Channels; System Interrupts - Honeywell bendis king KLN 94 Maintenance Manual

Table of Contents

Advertisement

BENDIX/KING
SYSTEM
ANALOG
ANALOG SIGNALS
CHANNELS
ADA0
DIM_POT_SENSE Monitors the setting of the Switch Board U7005 pot setting.
ADA1
ADA2
DIM_BUS_SENSE Monitors the setting of the aircraft's lighting bus.
ADA3
DISPLAY_TEMP
ADA4
ADA5
ADA6
ADA7
BAT_MEAS
The Host microprocessor can monitor up to 7 interrupts of which only 4 are used. The following
table shows the descriptions of the interrupts monitored.
SYSTEM
INTERRUPT
INTERRUPTS
SIGNALS
IRQ1
DPRAM_INTLn
IRQ2
DBTX_INTn
IRQ3
GLUINTn
IRQ4
DBRX_INTn
IRQ5
NC
IRQ6
NC
PF7
POWER_SHUTDOWNn
Upon the release of MAIN_HW_RESETn, the Host microprocessor starts addressing code space
data from the programmed flash part (U5010) starting with all address lines low as the first ad-
dress. The memory map of the Host microprocessor is depicted in the following table.
Page 4-28
DIGTEMP
Measures unit temperature.
Measure of the Backlight LED's temperature.
PWRBUS
Samples unit bus voltage selected by U5020.
OBSSIN
Monitors SIN ouput of OBS resolver.
OBSCOS
Monitors COS ouput of OBS resolver.
Measures battery level.
TABLE 4-2 ADC Channels
TABLE 4-3 System Interrupts
15599M00.JA
DESCRIPTIONS
DESCRIPTIONS
U5008 interrupt for Dual Port Ram operation.
DUART database loader transmit ready.
DUART GPS transmit ready/receive interrupt.
DUART database loader receive ready.
Pulled High.
Pulled Low.
Port pin F7 is used as an output to shutdown the unit
via S/W, rather than as an interrupt.
KLN 94