Verify the NV BATTERY reading is not less than 3.3VDC.
K.
If no failures are indicated, record the voltage reading on the Final Data Sheet.
L.
Verify the DIGITAL 5V reading is between +4.75VDC and 5.25VDC.
M.
If no failures are indicated, record the voltage reading on the Final Data Sheet.
N.
Verify the RF 5V reading is between +4.75VDC and 5.25VDC.
O.
If no failures are indicated, record the voltage on the Final Data Sheet.
5.2.4.13
ANALOG INPUT TEST
A.
Turn the right inner knob to the next display, which appears below.
B.
Verify the reading for the AC POWER MONITOR is between +10.7 and +33.7VDC.
C.
Verify the reading for the PROT AC POWER is between +10.5 and +33.5VDC.
D.
If no failures are indicated, record the voltage on the Final Data Sheet.
5.2.4.14
UNIT TEMPERATURE SENSOR TEST
A.
Check the display listed above. Verify the unit temperature is not more than ambient
+35°C.
B.
If no failures are indicated, record the temperature reading on the Final Data Sheet.
5.2.4.15
DISPLAY PERFORMANCE TEST
A.
Turn the right inner knob of the unit to display the following page.
Page 5-14
N/V BATTERY
TST +3
AC Power Monitor
FILTER AC Power
Unit Temp
TST +3
15599M00.JA
P/S 5V
P/S RF 5V
KLN 94
3.7V
5.0V
5.1V
13.7V
13.7V
44.7°C