Cisco Prisma II Installation And Operation Manual page 62

Prisma ii high density dual reverse receiver
Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Chapter 2 Module Installation
Example 2: Multiple Chassis Configuration
This example shows the control parameter values needed to define a more complex
Master-Slave relationship among four individual receiver channels in slots 6 and 27
of chassis 31 and slots 5 and 10 of chassis 11.
HD-RxR in slot 5 (Slave)
HD-RxR in slot 6 (Slave)
In this example:
Receiver 1 in slot 27 of chassis 31 is backed up by receiver 1 in slot 5 of chassis 11.
Receiver 2 in slot 27 of chassis 31 is backed up by receiver 1 in slot 10 of chassis
11.
Receiver 2 in slot 5 of chassis 11 is backed up by receiver 1 in slot 6 of chassis 31.
Receiver 2 in slot 10 of chassis 11 is backed up by receiver 2 in slot 6 of chassis 31.
This configuration takes advantage of the ability to configure each receiver channel
individually to provide greater flexibility in defining Master-Slave relationships.
38
Prisma XD Chassis with ICIM
Prisma II Chassis (no ICIM)
P
S
Control
Slot 5 Settings
Mode
Independent
Mode1
Slave
Mode2
Master
Alarm1
Off
Alarm2
Off
Red1Chas
31
Red1Slot
27
Red1Sub
1
Red2Chas
31
Red2Slot
6
Red2Sub
1
Chassis ID = 11
ICIM-out to ICIM-in cables, 2m long
(PN 180143)
HD-RxR in slot 10 (Master)
Chassis ID = 31
ICIM bus terminator
(PN 4013014) required at end of
daisy chain.
HD-RxR in slot 27 (Master)
Slot 10 Settings
Slot 6 Settings
Independent
Independent
Slave
Slave
Master
Slave
Off
Off
Off
Off
31
11
27
5
2
2
31
11
6
10
2
2
Slot 27 Settings
Independent
Master
Master
Off
Off
11
5
1
11
10
1