Phone Communication Testing

Central Station Communication

¾
To perform a Central Station Communication Test:
1. Contact the central monitoring station and inform the operator that you are testing the system.
Also, inform the homeowner of all system pagers or voice event notification phones.
2. Test each sensor.
3. After you have completed the test, contact the central monitoring station to verify each alarm
was received.
• Refer to Table 8 for a complete list of Reporting Codes.

Pager Communication

¾
To perform a Pager Communication Test:
1. Contact the central monitoring station and inform the operator that you are testing the system.
Also, inform the homeowner of all system pagers or voice event notification phones.
2. Set the pager to ON.
3. Test each sensor.
• Refer to Table 8 for a complete list of Reporting Codes.
Event
Auto Phone Test
Manual Phone Test
RF Sensor Failure:
Smoke
Panic
PIR
Repeater
CO
Activity
Water
Emergency
Freeze
Call Button
AC Failure
AC Restore
Enter Programming
Exit Programming
Water Sensor
CO Detector
Activity Timer Failure
Medication Failure
Alarm Cancel
Smoke Detector
Audio Listen (Instant)
Audio Listen (Call Back)
Emergency Sensor (RF)
Table 8: Reporting Codes
SIA Code
CID Code
RP
1602
RX
1601
FS
1381
MS
1381
US
1381
QS
1381
GS
1381
US
1381
WS
1381
MS
1381
ZS
1381
MA
1100
AT
1301
AR
3301
LB
1627
LX
1628
WA
1154
GA
1151
NA
1102
MS
1641
OC
1406
FA
1110
L90
1606
X Audio
1411
MA
1100
Pager Code
N/A
-101-101
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
-107-107
-103-103
-102-102
-122-122
-122-122
-121-121
-119-119
-105-105
-104-104
-123-123
-109-109
N/A
N/A
-107-107
26

Advertisement

Table of Contents
loading

Table of Contents