When your system detects a problem, trouble beeps sound to alert you. See "Troubleshooting"
for an explanation of the causes of trouble beeps and what you can do to fix the problem.

Manual Tests

The automatic tests your system performs provide continuing reassurance that it is working prop-
erly. There are also weekly system tests you can do yourself as an added safeguard. Taking time
to do these tests will familiarize you with your system and alert you to anything unusual, such as
cut phone lines or sensors that have been tampered with.
The ability to conduct sensor and phone tests is a code attribute given per User code. Check the
Appendix A User Sheets to see which access codes have the ability to conduct these tests.

Sensor Test

This test verifies that the sensors in your system are operating correctly.
¾
To initiate a sensor test
1. Press 8 + Code + 3 . Touchpads display, "Press Status. System Armed to Sensor Test," or
"*SENSOR TEST nn MINUTES LEFT." When less than 5 minutes remain to the Test Mode
time, the system sounds a short beep every 60 seconds.
2. Use the procedures listed in Table 1 to test the individual sensors.
3. If you need more time to complete testing, restart the timer by pressing 8 + Code + 3 .
4. Check to see that all sensors have been tested by pressing
untested sensors.
5. You will know that you have finished testing when touchpads display, "SENSOR TEST OK"
or "ZONES ALL TESTED."
6. Disarm to Level 1 to exit Test Mode.

Phone Communication Test

The purpose of this weekly test is to verify that the connection between the central monitoring
station and your system is working properly.
Most phone tests take only a few minutes, however, your system will try for up to 15 minutes to
establish a connection.
After the test has started, the arming level can be changed to Level 2—Stay or Level 3—AWAY.
¾
To perform a phone communication test:
1. Contact the central monitoring station to inform them that you want to test the phone commu-
nication of your system.
2. Disarm the system.
8
3. Press
+ System Master Code +
TEST," or "PHONE TEST."
On fixed display touchpads:
After the phone test is complete, the touchpad displays "PHONE TEST OK." Press
If the phone test is successful, the touchpad displays "System Phone Test Alarm Mem-
ory" or "Phone Test Memory" briefly, then returns to a normal text display. Press
second time and the touchpad displays "System is OK."
If the phone test is unsuccessful, the touchpad displays "Memory Test Phone" briefly,
then "Alarm Memory Phone Failure."
On alphanumeric touchpads:
If the phone test is successful, the touchpad display returns to a normal text display.
If the phone test is unsuccessful, the touchpad displays "SYSTEM PHONE TEST
ALARM," then, "MEMORY," and finally, "PHONE FAILURE ALARM MEMORY."
If a phone test is unsuccessful, check to see if you hear a dial tone from phones in the house. Call
your dealer if you hear a dial tone, but your phone test is unsuccessful.