Deleting a
Sensor
System
Monitoring
23
As the installer, you are the only person authorized to delete a learned sensor from panel memory.
After programming a sensor, if the customer wants it deleted from panel memory, they must con-
tact their installer. To delete additional sensors, repeat the steps 3-5 as necessary.
¾
To delete a sensor:
1. Open the panel cover and insert the Installer Template over the panel menu.
2. Enter Utility Access Code 1 or Utility Access Code 2.
3. Press Delete. The panel announces "Select from Main Menu."
4. Press Sensor until the panel announces the correct sensor number to be deleted.
5. Press Done. The sensor is deleted.
To ensure proper operation, the panel constantly monitors for the following system conditions:
AC Power; Backup Battery; Sensor Low Battery; Sensor Supervisory Failure; Repeater; Auto
Phone Test; Phone In Use; Away Mode Operation.

AC Power

When AC power is connected, the panel Power light remains lit. If AC power is disconnected,
the following events occur:
The panel Power light turns off.
After four minutes, a non-reporting AC Fail Report is sent to the event buffer.
After five minutes, trouble beeps sound. If Option 25 is ON, the panel continues to sound six
beeps each minute. If Trouble Beeps is OFF, the panel sounds one series of six beeps.
If AC Power Failure Report (Option 17) expires, the panel sends a report to the central moni-
toring station and pager.
Note
If the Status button is pressed during an AC power failure, the panel announces "AC power failure" and
system trouble beeps stop sounding for four hours.
When AC power is restored:
If an AC Fail Report was sent, the panel also sends a power restoral report to the central mon-
itoring station and pager. If an AC Fail Report was not sent, the restoral report is sent to the
event buffer and is considered a non-reporting event.
The panel Power light turns on.
All trouble beeps stop sounding.

Backup Battery

During an AC power failure or battery test, if the panel's backup battery reports a low battery
condition, the following events occur:
If CPU Low Battery Report (Option 18) is
central monitoring station and pager.
Trouble beeps sound.
Note
If Status is pressed during a low battery condition, the panel announces "System low battery" and sys-
tem trouble beeps stop sounding for four hours.
If the battery status changes during a sensor test and CPU Low Battery (Option 18) is set to ON, the
panel sends a low battery or battery restoral report to the central station.

Replacing a Backup Battery

¾
To replace a backup battery:
1. On the panel's back, set the Power switch to OFF.
2. Remove the panel cover.
3. Remove speaker screws, battery cover screw, and battery cover (see Figure 6).
4. Remove the battery and disconnect battery cables.
, the panel sends a Low Battery Report to the
ON

Deleting a Sensor