Option 28: Access Code Length

The Access Code Length option allows you to set the number for each
access code to three, four, five, or six digits. Deleting the option resets each
access code and code length to the panel default.
¾
Please read the following prior to changing Option 28:
Option 28 effects each programmed access code.
Changing an access code length resets Utility Access Code 1, Utility
Access Code 2, Master Access Code, and Access Codes 1–5. See Table
6 for a complete list of code length default settings.
Note
Set the Access Code Length prior to programming a new access code.

Option 29: Panic Answer

The Panic Answer option allows you to answer and hang up a phone call by
pressing the personal help button or panel Call button.
If you answered the phone through the personal help button, ensure you use
the same help button to hang up the phone.

Option 30: Demo Mode

When Demo Mode is set to ON, the panel operates as a demonstration
model — no reports are sent to the central monitoring station. After a panic
button has been pressed, the panel announces "Contacting emergency num-
ber. Please remain calm." After a 10-second pause, the panel announces
"This is the response center, we have received your alarm. Do you have an
emergency?"
When set to OFF, the panel operates as a standard panel.
Note
When Demo Mode is set to ON, the panel does not monitor for CPU low battery.

Option 31: Report Program Mode

The Report Program Mode option allows the panel to send reports to the
central monitoring station each time a dealer or installer enters or exits the
Program mode (includes Utility Access Codes 1 and 2). In addition, reports
are also sent after the panel cover is opened and the Start button is pressed.
Programming Options
Table 6: Access Code Length Default Settings
Code Length
Default Code Setting
3
Master/Access 1-5 — 123
Utility 1 — 321
Utility 2 — 321
4
Master/Access 1-5 — 1234
Utility 1 — 4321
Utility 2 — 4321
5
Master/Access 1-5 — 12345
Utility 1 — 54321
Utility 2 — 54321
6
Master/Access 1-5 — 123456
Utility 1 — 654321
Utility 2 — 654321
Range = 3-6 (Default = 4)
¾
To program Access Code Length:
1. Press Add.
2. Press Option #.
3. Press 2, then 8.
4. Enter the desired Access Code Length.
5. Press Done.
Range = On/Off (Default = On)
¾
To program Panic Answer:
1. Press Add or Delete.
2. Press Option #.
3. Press 2, then 9.
4. Press Done.
Range = On/Off (Default = Off)
¾
To program Demo Mode:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 0.
4. Press Done.
Range = On/Off (Default = Off)
¾
To program Report Program Mode:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 1.
4. Press Done.