Antenna

The 7845GSM comes equipped with an internal antenna. This feature provides additional
security to the installation by making the device tamper resistant.
AMPS antennas, such as the 7825-OC antenna, cannot be used with this product.

Specifications

Mechanical

Dimensions: 8.4" x 8.0" x 1.5"
Weight: 2.4 lbs., with battery

Electrical

Input Power: 9VAC, 15VA transformer, Honeywell part number 1332/1332CN in Canada
(included)
Backup Battery: 6V, 3.1AH, Honeywell part number K14139, (included)
Current Drain: 35mA average standby, 500mA peak transmit
Fault Relay Output: Open collector, 12VDC, .25W max.
Input Trigger Levels: (V+) 2V – 13V
RF
Transceiver Type: Tri-Band GSM/GPRS Class 10
Modulation: GMSK
Antenna: Internal GSM quad-band antenna 1.3 dBi gain
Transmission
Frequency
Band
(MHz)
GSM 850
824-849
GSM 1800
1710-1785
GSM 1900
1850-1910

Environmental

Operating temperature: -20º to +55ºC
Storage temperature: -40º to +70ºC
Humidity: 0 to 90% relative humidity, non-condensing
Altitude: to 10,000 ft. operating, to 40,000 ft. storage
WWW.DIYALARMFORUM.COM
(V-) 0V – 1V
Transmit
Power
Frequency
(dBm)
33
33
1805-1880
33
1930-1990
WWW.DIYALARMFORUM.COM
Receive
Receive
Sensitivity
(MHz)
(dBm)
869-894
-107
-106
-105.5
Section 1: General Information
Number
Channel
of
Spacing
Channels
(MHz)
124
200
374
200
299
200
Duplex
Separation
(kHz)
45
95
80
1-3