Honeywell AlarmNet 7845GSM Installation And Setup Manual page 28

Digital cellular communicator
Hide thumbs Also See for AlarmNet 7845GSM:
Table of Contents

Advertisement

7845GSM/7845GSMCN Installation and Setup Guide
PROMPTS
Restore Zn2 Y/N
32
(Y)_
Delay Zn2 (secs)
33
(00)_
Rpt Zn2 ONLY if
34
Armed (N)_
If Lynx Panic is enabled, then skip to Prompt 39: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
35
(V+)_
Invert Zn3 Y/N
36
(N)_
Restore Zn3 Y/N
37
(Y)_
Delay Zn3 (secs)
38
(00)
Rpt Zn3 ONLY if
39
Armed (N)_
Zn4 Trigger Type
40
(V+)_
41
Invert Zn4 Y/N
(N)_
42
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
43
(00)
Rpt Zn4 ONLY if
44
Armed (N)_
Zn5 Trigger Type
45
(V+)_
Invert Zn5 Y/N
46
(N)_
3-14
WWW.DIYALARMFORUM.COM
ZONE
4204/
ENTRY
TRIG.
2-4204
2-
4204
only
WWW.DIYALARMFORUM.COM
OPTIONS
[Y], [N]
Enables restore reporting for zone 2.
[01-15]
Defines the reporting delay in seconds for zone 2.
[00] = no delay
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 3.
[01-15]
Defines the reporting delay in seconds for zone 3.
[00] = no delay
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to
"Report Only if Armed," skip to Prompt 50:
"Enable Zn6."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 4.
[01-15]
Defines the reporting delay in seconds for zone 4.
[00] = no delay
[Y], [N]
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
5 trigger; otherwise uses normal input signal.
DESCRIPTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alarmnet 7845gsmcn

Table of Contents