7845GSM/7845GSMCN Installation and Setup Guide
PROMPTS
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
(Y/N)_
Device Mode
9
(ECP)_
Important Information Regarding Primary and Secondary Accounts (Questions 10-16)
Account information is provided by the central station administrator. If the control supports secondary account
reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the secondary
account must differ from that of the primary account.
Primary City ID
10
(??)_
Primary CS ID
11
(???)
Primary Sub ID
12
(????)
nd
En. 2
CS Y/N
13
(N)_
nd
2
City ID
14
(??)_
nd
2
CS ID
15
(??)_
nd
2
Sub ID
16
(????)_
Device Address
17
(03)_
3-4
WWW.DIYALARMFORUM.COM
ENTRY
OPTIONS
[0-9, A-F, N,
S, T, X, Y]
[0-9, A-F, N,
S, T, X, Y]
[Y], [N]
[ESC]
• ECP
• Zone Trig.
• 4204 Emu
• Two 4204s
[01-99]
[01-FE]
[0001-9999]
[Y], [N]
[01-99]
[01-FE]
[0001-9999]
[01-30]
WWW.DIYALARMFORUM.COM
DESCRIPTION
This prompt is displayed if [Y] was pressed in Prompt 4
or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the
following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed
directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in
this section.
Press the [space] key to scroll through the modes of
operation.
Press [ENTER] to select ECP mode.
See Table 5 if programming other modes.
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
Applicable only if control supports Central Station #1
and #2 Category Enable reporting for the LRR device
(e.g., VISTA-128BP, FA1660C, etc.).
Used if reporting to a second central station is desired.
If [N], go to Prompt 17: "Device Address."
Enter the 2-digit secondary city ID, 01-99 (decimal).
Enter the 2-digit second central station's ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number for the
second central station, 0001-9999.
In ECP mode, the 7845GSM communicates with the
panel as a Long Range Radio (LRR) device. Enter the
appropriate ECP device address. For VISTA-10 and
VISTA-20 series control panels, use address 03. For
other controls, see the control panel's Installation and
Setup Guide.
NOTES:
1. When programming the control, enable the LRR
output.
2. The device address must be unique from the
"Direct Wire Addr" entered in Prompt 19.