Honeywell AlarmNet 7845GSM Installation And Setup Manual page 24

Digital cellular communicator
Hide thumbs Also See for AlarmNet 7845GSM:
Table of Contents

Advertisement

7845GSM/7845GSMCN Installation and Setup Guide
PROMPTS
Exit Prog. Mode?
8
(Y/N)_
Device Mode
9
(ECP)_
Account information is provided by the central station administrator.
Primary City ID
10
(??)_
Primary CS ID
11
(???)
Primary Sub ID
12
(????)
Device Address
13
(12)_
Enable DW Y/N
14
(N)_
Direct Wire Addr
15
(28)_
3-10
WWW.DIYALARMFORUM.COM
4204/
ZONE
ENTRY
2-4204
TRIG.
Important Information Regarding Primary Account (Questions 10-12)
WWW.DIYALARMFORUM.COM
OPTIONS
Exits program mode.
[Y], [N]
Press [N] to go back to Prompt 3.
[ESC]
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph
in this Section.
• ECP
Press the [space] key to scroll through the modes of
operation.
• Zone Trig.
Press [ENTER] to select the mode of operation.
• 4204 Emu
• Two 4204s
See Table 3 for ECP mode programming.
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
[0001-9999]
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
The 7845GSM communicates with the control
[01-15]
panel as a 4204 relay module. Enter the
appropriate address. For VISTA-10P and
FA130CP Series control panels, this must be
address 12. For other controls, see the control
panel's Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15.
If using 2-4204 mode, the 7845GSM assigns the
second 4204 to the next higher device address
(e.g., if entering address 12 for the first 4204,
then address 13 is automatically assigned to the
second 4204 module). Program the control panel
accordingly.
2. The device address(es) must be unique from the
"Direct Wire Addr" entered in Prompt 15 and
any other address used on the control panel.
Applies only to VISTA-128BP/250BP and FBP
[Y], [N]
Series controls, and FA1660C and 1700C Series
controls.
Enables Direct Wire Downloading over GSM.
If [N], skip to Prompt 16: "Supervision."
When using Direct Wire downloading, the
[01-30]
7845GSM communicates with the panel as an
alpha keypad to initiate the direct wire download
session. Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an
alpha keypad in the control panel (Device
Programming Mode). DO NOT connect an
actual keypad (or any other device) assigned to
this address.
2. This address must be unique from the "Device
Address" entered in Prompt 13, and cannot
equal that device address plus 1 (one) if using
2-4204 mode.