Site Hardware
Connection to an Alarm Panel
Fault Relay Hardware
60
Connect a combination of Fault Relay circuitry and outputs to an alarm panel, preset to
warn your organization if a failure occurs. An output can be configured to respond to a
Response Schedule.
Figure 5-5
Connecting the DVR FAULT RELAY to an External Alarm Panel
Fifteen-Minute Delay
If the DVR fails to function, report alarms or record video due to hardware failure, for more
than 15 minutes, the FAULT RELAY is triggered.
Immediate Trigger
A power outage triggers the relay immediately.
Caution
Do not connect a device to CONTROL output 6 after enabling the FAULT
RELAY.
Enabling the FAULT RELAY provides a status pulse at CONTROL 6,
disabling it as a general-purpose output. Connecting a device to
CONTROL 6 could interfere with the relay's performance.
+
INPUT to
-
external
alarm
panel