Honeywell GSMX Installation And Setup Manual page 17

Gsm communicator
Table of Contents

Advertisement

GSMX Installation and Setup Guide
PROMPTS
ENTRY
NOTE: Prompts 10 and 11 only appear if the Multi-Mode feature has been enabled.
Setting up E-mail Notifications (Multi-Mode feature)
NOTE: E-mail notification is intended as a convenience for the user, and does
not replace Central Station reporting of critical events (alarms, troubles, etc.).
Users can receive e-mail notification of system events by using the Multi-Mode
feature. The following items must be met to use this feature.
The Multi-Mode feature must be enabled during account programming on the
AlarmNet Direct website by selecting "Enabled" at Multi-Mode prompt.
The GSMX will emulate one or two 4204 relay modules to accommodate system
events that are programmed in the control panel. When programming the
GSMX, at prompt #10, choose 4204-Sourced so the user can be notified of up to
four events, or choose 2-4204-Sourced so the user can be notified of up to eight
system events.
The 4204 relay events used to trigger email notifications are defined on the
Honeywell Total Connect website, and must correspond to outputs (relays)
programmed in the control panel through Output Device programming.
The Multi-Mode address selected at prompt #11 in the GSMX (or at the
AlarmNet Direct website) must match the address of a 4204 relay module
enabled in the control panel (although you don't actually connect a module).
If using "2-4204-sourced," the address of the second module is automatically
assigned the next device address after the first 4204. Make sure that address is
also enabled in the control panel.
10
Multi Mode
(Disabled)_
11
Multi Mode
Addr
(12)
OPTIONS
• Disabled
Enable if you want system events
sent by e-mail to the user. Select
• 4204
"4204 Sourced" to send up to four
Sourced
events, or "2-4204 Sourced" to
• 2-4204
send up to eight events.
Sourced
Disable for normal alarm
processing and go to Prompt 12
"Primary City ID" prompt.
[01-30]
This address must be
programmed if using the Multi-
Mode (e-mail notification)
feature. The device address must
be unique from the normal LRR
Device Address and the Keypad
Address used for Remote Access
or Direct Wire downloading.
The address used must also be
enabled as a 4204 relay module in
Vista and First Alert control
panels.