GSMX Installation and Setup Guide
4204 Relay Outputs map to zones
First 4204 Zones (device
address entered in Prompt 15):
Relay 1 = Zone 1
Relay 2 = Zone 2
Relay 3 = Zone 3
Relay 4 = Zone 4 or conditional
zone trigger if "report only if
armed" is selected in any zone 1-3
when using single 4204 mode.
NOTE: Zone 4 status is not
reported when being used as the
conditional (armed) trigger zone.
When using the module in 4204 Emulation Mode, DO NOT enable the Long-
Range Radio module in control panel programming. Instead, enable 4204
relay module address(es) and program the appropriate relay activation
functions for the relay-zones being used. In some control panels, it is called
"relay programming" and in others it is called "output device programming."
It is recommended that "close and stay closed" (usually choice 2) action is
selected. Selection of momentary activation will cause the communications
module to generate an alarm and NOT a restore, even if the module is
programmed to send a restore for the given zone.
In 4204 mode, messages are reported in ADEMCO High-Speed format. Zone
alarms
(status 7) are reported with "1" (alarm) or "3" (restore) displayed in the zone
position for the respective zone (e.g. alarm on zone 2: 5155 5555 7; restore
5355 5555 7). A supervision fault trouble message is automatically sent if the
module detects no activity on its connection to the control. The message is:
5555 5515 5; restore message is: 5555 5535 5.
Second 4204 Zones (device address
entered in Prompt 15, plus 1):
Relay 1 = Zone 5
Relay 2 = Zone 6
Relay 3 = Zone 7
Relay 4 = Zone 8 or conditional zone
trigger if "report only if armed" is
selected in any zone 1-7 when using
Two-4204 mode.
NOTE: Zone 8 status is not reported
when being used as the conditional
(armed) trigger zone or if tamper
reporting is enabled.