Cable Connector Configurations - Honeywell StratosH MS2320 Installation And User Manual

Stratosh scanner / diva scale
Hide thumbs Also See for StratosH MS2320:
Table of Contents

Advertisement

S
C
CANNER AND
ABLE
C
C
C
ABLE
ONNECTOR
ONFIGURATIONS
The following cables are examples of some of the standard cables that may be shipped with the StratosH scanner.
Please keep in mind that every application is unique and the cables received with the StratosH may be custom cables that are not
shown below.
RS232 Interface Cable,
Pin
1
Shield Ground
2
RS232 TX Output
3
RS232 RX Input
4
DTR Input
5
Signal Ground
6
No Connect
7
CTS Input
8
RTS Output
9
No Connect
Full Speed USB Cable,
57-57200x-N-3 OR
PN
Pin
1
PC+5V USB
2
Data -
3
Data +
4
Signal Ground
RS485 Cable,
Pin
1
Signal Ground
2
IBM A+
3
IBM B-
4
No Connect
OCIA Cable,
Pin
1
Shield Ground
2
R Data
3
R Data Return
4
Clock Out
5
Signal Ground
6
Clock In Return
7
Clock Out Return
8
Clock In
9
No Connect
** All signals referenced from the StratosH scanner.
Specifications are subject to change without notice.
58
T
ERMINATIONS
57-57000x-N-3
PN
**
Function
57-57006x-N-3
PN
**
Function
57-57004x-N-3
PN
**
Function
57-57015x-N-3
PN
**
Function
9-Pin D-Type Connector
Locking, Type A
57-57200x-N-3
4-Pin SDL
9-Pin D-Type Connector
Non-Locking, Type A