Honeywell StratosH MS2320 Installation And User Manual page 61

Stratosh scanner / diva scale
Hide thumbs Also See for StratosH MS2320:
Table of Contents

Advertisement

T
ROUBLESHOOTING
Symptom
All Interfaces
Scanner beeps at some bar
codes and NOT for others of
the same bar code
symbology.
RS232 Only
The unit powers up OK and
scans OK but does not
communicate properly to the
host.
The host is receiving data
but the data does not look
correct.
Characters are being
dropped.
Aux Port Operation With Any Interface
The secondary scanner is
not functioning.
The secondary scanner
powers up but data is not
relayed to the host.
* Refer to the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (
Bar Codes: Auxiliary Port, Quick Start for a Secondary Honeywell Scanner.
Possible Cause(s)
Check the character length
lock.
The aspect ratio of the bar
code is out of tolerance.
The bar code may have been
printed incorrectly.
The scanner is not configured
correctly for this type of bar
code.
The minimum symbol length
setting does not work with the
bar code.
The com port at the host is not
working or is not configured
properly.
The cable is not connected to
the proper com port.
The com port is not operating
properly.
The scanner and host may not
be configured for the same
interface.
The intercharacter delay needs
to be added to the transmitted
output.
The secondary scanner cable
may not be connected to the
proper port on the StratosH.
The auxiliary com port may not
be operating properly.
Check if it is a check digit, character or border problem.
Check if check digits are set properly.
Check if the correct minimum symbol length is set.
Check to make sure that the baud rate and parity of the scanner
and the communication port match and the program is looking for
RS232 data.
Check that the scanner and the host are configured for the same
interface.
Add some intercharacter delay to the transmitted output
by using the MetroSelect Configuration Guide
(
00-02407x).
PN
Refer to the user's guide provided with the secondary scanner.
Ensure that the secondary scanner is connected to the StratosH's
com port marked "Aux" port.
* The StratosH must be configured to enable the auxiliary port.
The auxiliary input port's data format must match the main output
format of the secondary scanner.
00-02272x) under Scanner Configuration
PN
Solution
55

Advertisement

Table of Contents
loading

Table of Contents