The following steps describe how to properly install the cables for an OCIA StratosH application. The scanner/scale must then be
configured to match the host's OCIA parameters. Cable installation alone does not guarantee that the StratosH will communicate
properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide (
Scanner/Diva Scale Configuration Addendum (
1.
Turn off the host system.
2.
Plug the 10-pin RJ45 end of the OCIA interface cable (
on the bottom of the StratosH. Refer to figure on page 24.
3.
Connect the other end of the OCIA Interface cable (
Before continuing verify that the OCIA cable pinouts match the host system's and is connected to the appropriate interface
socket on the scanner. An incorrect cable connection can cause communication problems or potential damage to the
scanner and/or terminal.
Manufacturers Note: Plugging the scanner into the serial port of the host device does not guarantee that scanned
information will appear at the host device. A software driver and correct configuration settings are also required for proper
communication to occur.
Steps 4 and 5 are for dual cable interfaces where the scale and the scanner connect to the host with their own separate
communication cables. Skip to step 6 for a single cable interface where the scale and scanner connect to the host with a single cable.
4.
Plug the dual interface cable (
StratosH.
5.
Connect the other end of the dual interface cable (
device.
6.
Plug the optional remote display cable** into the 10-pin socket labeled, Scale to Display, on the bottom of the StratosH.
** See page 3 for information on optional display types and part numbers.
7.
Plug the external power supply (
the StratosH.
xxx*
Specifies international connection. See Optional Accessories in the Introduction section of this guide for a complete listing.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should
be located near the equipment and be easily accessible.
Honeywell recommends using a switched AC outlet. The switch should be located on the operator's side of the checkout
counter in close proximity to the StratosH to facilitate calibration and service of the unit.
S
)
NTERFACE
PECIFIC
57-57000x-N-3) into the 10-pin socket labeled, Scale RS232 to Host, on the bottom of the
PN
xxx*
46-46
) into the 3-pin Molex socket labeled, DC Power In, on the bottom of
PN
00-02272x).
PN
57-57015x-N-3) into the 10-pin socket labeled, Scanner OCIA to Host
PN
57-57015x-N-3) to the appropriate communication port on the host device.
PN
57-57000x-N-3) to the appropriate communication port on the host's scale
PN
00-02407x) and the MS2x20 Stratos Series
PN
23