To change the factory-set alarm setpoints, refer to
ting Alarm
Setpoints.
To disable an alarm, set the alarm setpoint to 0 (zero).

Stopping a Gas Alarm

The low and high alarms stop when the ambient gas level returns to
below the low alarm setpoint.
If alarms are set to latch, press C to reset the alarms.
Follow all safety procedures as defined by your
employer. Confirm with your supervisor before clearing
TWA and STEL alarms.
The TWA and STEL alarms can be stopped either by
• clearing the MAX, TWA, and STEL exposures (refer to
Gas
Exposures), or
• deactivating the detector for 5 minutes (minimum) and then
reactivating it again.
Calibration and Set-
Note
Note
a Caution

Sensor Alarm

The detector tests for missing or defective sensors during the activation
self-test. If a sensor fails the self-test, FAIL flashes on the LCD above
the failed sensor. Refer to Troubleshooting.

Pump Alarm

The external pump draws air over the sensors continually. If the pump
stops operating or becomes blocked, the detector activates the pump
alarm. The following screens display.
Clearing
The pump alarm continues until the blockage is cleared or it is
acknowledged by pressing C. If C is pressed, the detector automati-
cally launches a pump test to reset the pump module.
GasAlertMicro 5/PID/IR
Alarms
43